LucaCarMods
NTC sensor calibration
Choose a sensor or enter the datasheet values and create the calibration for your ECU.
The calculator has not loaded. Check if JavaScript is enabled and refresh the page.
{"settings":{"eyebrow":"LucaCarMods","heading":"NTC sensor calibration","intro":"Choose a sensor or enter the datasheet values and create the calibration for your ECU.","heading_tag":"h1","layout":"split","density":"compact","width":1120,"input_percent":45,"gap":16,"padding_top":24,"padding_bottom":32,"radius":8,"font_size":14,"title_size":32,"heading_align":"left","sticky":false,"sticky_top":24,"show_graph":true,"show_table":true,"show_steps":true,"show_source":true,"allow_custom":true,"palette":"light","bg":"#f3f4f6","panel":"#ffffff","soft":"#f7f8fa","line":"#d9dde3","text":"#181b20","muted":"#606873","accent":"#bd5700","button_text":"#ffffff","error":"#b42318"},"blocks":[{"id":"b0","type":"sensor","settings":{"title":"Bosch NTC M12-L · 0 280 130 039","part":"","usage":"Intake air temperature","info":"Air temperature sensor, M12×1.5. Official Bosch table from −40 to 140 °C.","unit":"ohm","points":"-40;45313\n-30;26114\n-20;15462\n-10;9397\n0;5896\n10;3792\n20;2500\n30;1707\n40;1175\n50;834\n60;596\n70;436\n80;323\n90;243\n100;187\n110;144\n120;113\n130;89\n140;71","source":"https:\/\/www.bosch-motorsport.com\/content\/downloads\/Raceparts\/Resources\/pdf\/Data%20Sheet_70129803_Temperature_Sensor_NTC_M12-L.pdf","enabled":true}},{"id":"b1","type":"sensor","settings":{"title":"Bosch NTC M12 · 0 280 130 026","part":"","usage":"Fluid temperature","info":"For oil, water or fuel, M12×1.5. Official Bosch table from −40 to 130 °C.","unit":"ohm","points":"-40;45313\n-30;26114\n-20;15462\n-10;9397\n0;5896\n10;3792\n20;2500\n30;1707\n40;1175\n50;834\n60;596\n70;436\n80;323\n90;243\n100;187\n110;144\n120;113\n130;89","source":"https:\/\/www.bosch-motorsport.com\/content\/downloads\/Raceparts\/Resources\/pdf\/Data%20sheet_70101387_Temperature_Sensor_NTC_M12.pdf","enabled":true}},{"id":"b2","type":"sensor","settings":{"title":"Bosch PST-F1 · 0 261 544 01F","part":"","usage":"Fluid temperature","info":"Only the NTC temperature channel of the combined 0–10 bar pressure sensor. Bosch specifies −40 to 150 °C and an optimal external pull-up of 4.6 kΩ. The 0.5–4.5V pressure channel is not calibrated here.","unit":"ohm","points":"-40;44864\n-30;25524\n-20;15067\n-10;9195\n0;5784\n10;3740\n20;2480\n30;1683\n40;1167\n50;824\n60;594\n70;434.9\n80;323.4\n90;244\n100;186.6\n110;144.5\n120;113.3\n130;89.9\n140;71.9\n150;58.1","source":"https:\/\/www.bosch-motorsport.com\/content\/downloads\/Raceparts\/Resources\/pdf\/Data%20sheet_70496907_Pressure_Sensor_Combined_PST-F_1.pdf","enabled":true}},{"id":"b3","type":"sensor","settings":{"title":"AEM 30-2013 \/ 30-2014","part":"","usage":"Air or liquid temperature","info":"AEM Pro temperature sensors for air or liquid. The official range is from −20 to 150 °C.","unit":"ohm","points":"-20;28136\n-10;15813\n0;9319\n10;5589\n20;3476\n30;2230\n40;1466\n50;984\n60;671\n70;468\n80;332\n90;239\n100;175\n110;129\n120;97\n130;73\n140;57\n150;43","source":"https:\/\/documents.aemelectronics.com\/techlibrary_30-2013_temp_sensor_kit.pdf","enabled":true}},{"id":"b4","type":"sensor","settings":{"title":"GM\/Delphi 25036751","part":"","usage":"Intake air temperature","info":"Widely used open-element IAT sensor. Exact specifications from the archived Delphi product specification, from −40 to 150 °C.","unit":"ohm","points":"-40;99326\n-30;51791\n-20;28146\n-10;15873\n0;9256\n10;5572\n20;3457\n30;2205\n40;1443\n50;965\n60;660\n70;462\n80;329\n90;238.1\n100;175.3\n110;131\n120;99.4\n130;76.4\n140;59.4\n150;46.7","source":"https:\/\/pe-ltd.com\/assets\/air_temp.pdf","enabled":true}},{"id":"b5","type":"texts","settings":{"sensor":"Sensor","sensor_intro":"Choose a sensor from the list or enter the manufacturer's values.","preset_route":"Known sensor","custom_route":"Own sensor","choose_sensor":"Choose a sensor","sensor_name":"Sensor name or part number","sensor_placeholder":"For example, Bosch 0 280 …","usage":"Application","coolant":"Coolant temperature","air":"Intake air temperature","oil":"Oil temperature","fuel":"Fuel temperature","other":"Other temperature","values":"Sensor values","values_help":"Use at least three points from the datasheet regarding the desired temperature range.","preset_help":"Values from the sensor table. Check the part number.","unit":"Resistance unit","temperature":"Temperature","resistance":"Sensor resistance","voltage":"Expected voltage","add":"Add measurement point","remove":"Remove measurement point","clear":"Clear table","ecu":"ECU","choose_ecu":"Select your ECU","input_type":"ECU input type","temp_input":"Special temperature\/thermistor input","analog_input":"Open analog 0–5V input + external pull-up","pullup":"Pull-up resistance","supply":"Pull-up tension","advanced":"Adjust pull-up tension","selection":"Your selection","chart":"Temperature and resistance","chart_desc":"Temperature versus sensor resistance on a logarithmic scale.","instructions":"Settings in the ECU","datasheet":"Datasheet","not_calculated":"Not calculated","custom_name":"Proprietary NTC sensor","result_button":"View ECU settings","no_sensors":"No sensor presets are available. Enter your own datasheet values.","range":"{min} to {max} °C","point":"Measuring point {number}","axis_r":"Resistance (Ω, logarithmic)","axis_t":"Temperature (°C)","other_ecu":"Other standalone ECU"}},{"id":"b6","type":"help","settings":{"ntc_help":"Use manufacturer data. For an NTC, the resistance decreases as the temperature rises.","pullup_help":"Quick choices: 2.2 kΩ, 2.7 kΩ and 4.7 kΩ. Choose the value according to the sensor and ECU specifications and enter the actual installed resistance.","supply_help":"Normally use the regulated 5V sensor power supply from the ECU.","voltage_help":"The voltage is calculated using the specified pull-up and power supply. Check whether your ECU expects a calibration resistor or voltage.","analog_notice":"Use an available 0–5V input that can be assigned to the desired temperature function in the ECU software. Connect the NTC between signal and Sensor Ground; place the external pull-up between signal and the regulated 5V sensor supply.","choose_ecu_help":"Select your ECU and input to view the settings.","internal_hint":"Internal pull-up: {value} Ω. This value applies to the special temperature input.","unknown_hint":"Check the internal pull-up of this input in the ECU manual and enter the value.","analog_steps":"Connect the free analog input to the desired temperature function.\nInstall the external pull-up and enter the exact value above.\nRefer to the correct temperature\/resistance or temperature\/voltage table according to the ECU software.\nCheck the live temperature with a cold and hot sensor.","empty":"Enter at least three complete measurement points.","partial":"At each measuring point, enter both the temperature and the resistance.","bounds":"Use finite values: temperature −273.14 to 1000 °C; resistance 0.000001 to 10,000,000 Ω. These are input limits, not sensor ranges.","duplicate":"Each temperature may only occur once.","monotonic":"For an NTC, the resistance must decrease as the temperature rises. Also check Ω\/kΩ.","limit":"Use a maximum of 64 measurement points.","voltage_error":"No voltage detected. Check the pull-up resistor (1–10,000,000 Ω) and power supply (0.1–24 V).","sensor_error":"This sensor preset does not have a valid calibration. Choose a different sensor or use your own datasheet values.","startup_error":"The calculator has not loaded. Check if JavaScript is enabled and refresh the page."}},{"id":"b7","type":"ecu_guide","settings":{"ecu":"maxx","title":"Settings in MaxxECU MTune","notice":"Preferably use an AIN (TEMP). According to MaxxECU, this has a fixed 2.5 kΩ pull-up. A standard 0–5V input requires an external pull-up.","steps":"Choose the correct input. Open Inputs \/ Analog inputs and use an AIN (TEMP) for a passive NTC sensor.\nChoose the sensor function. For example, select Coolant temperature sensor, Intake temperature sensor, or Engine oil temperature.\nCreate your own calibration. Choose User-defined sensor and enter the temperature and resistance values from the table.\nCheck the live value. Compare the measured temperature when the engine is cold with the ambient temperature before using the engine."}},{"id":"b8","type":"ecu_guide","settings":{"ecu":"me","title":"Settings in Motorsport Electronics MEITE","notice":"The fixed internal 2.7 kΩ pull-up applies only to the special temperature inputs. Select the input type you are using below.","steps":"Use a temperature input. Choose the CLT or IAT temperature input. Only these inputs have the internal 2.7 kΩ pull-up.\nOpen the correct HRT. Use the CLT HRT for coolant or the IAT HRT for intake air.\nFill in the sensor table. Work in ohms. MEITE supports 16 HRT rows; choose points across the entire temperature range.\nCheck the live value. A value towards 5 V or very high resistance often indicates an open circuit or poor ground."}},{"id":"b9","type":"ecu_guide","settings":{"ecu":"ecumaster","title":"Settings in ECUMASTER","notice":"Enter the resistance\/temperature calibration in Sensors and inputs. Check the pull-up configuration of the selected input in your pinout and software version.","steps":"Open Sensors and inputs. Find the setting for CLT, IAT, or the analog input you use as a temperature sensor.\nChoose or create the calibration. Use a suitable built-in sensor or enter your own resistance\/temperature table.\nCheck the input. Verify in the pinout and built-in Help which pull-up is active for the selected input.\nSave permanently. Check the live temperature and use Make permanent (F2) once the values are correct."}},{"id":"b10","type":"ecu_guide","settings":{"ecu":"generic","title":"Settings in your standalone ECU","notice":"Check the ECU manual to see if the selected input has an internal pull-up and what value it uses.","steps":"Use a temperature input. Connect the sensor to a thermistor or temperature input and Sensor Ground.\nCheck the pull-up. Use the internal pull-up or install the external pull-up specified by the ECU manufacturer.\nEnter the sensor table. Use temperature in °C as the result and resistance in Ω as the sensor value.\nCheck before use. Compare the live temperature with a reliable reference when the sensor is cold and hot."}}]}